Effective date: October 8, 2026
Publisher: Marc Ammar
Contact: mammar@computercare.net
Applies to: the Event Bridge Chrome extension, version 0.2.0 and later

1. What Event Bridge does

Event Bridge is a work tool for authorized staff who process hardware in two supported internal web tools hosted at https://www.internalfb.com:

  • MES Reverse (paths beginning /inventory/manufacturing/reverse/triage), and
  • Track@ Repair (paths beginning /intern/track/repair).

When a signed-in user completes supported workflow steps in those tools, Event Bridge records the resulting workflow events on the user’s computer and sends them to ComputerCare Atrium (https://atrium.computercare.net), the operational system that receives these records. This is the extension’s single purpose. Event Bridge does not change anything in MES or Track@ Repair.

2. Information Event Bridge handles

2.1 Workflow and asset information (from the supported pages)

While the active page is one of the supported workflow routes, Event Bridge reads the responses of that page’s own workflow requests to determine what was done. From this it records:

  • Hardware identifiers and attributes: asset tag, serial number, serialized part ID, part number (FBPN), hardware model, subcategory, asset status, the hardware’s current physical location code, backup decision, end-of-life date, and repair-approval status, when MES provides them.
  • MES workflow details: event type (step started or step completed), workflow type (wipe, diagnostic, or backup), the current MES step, the pass/fail result recorded by MES, the locator used, and the verification time.
  • Track@ Repair details: repair ID, repair status, repair activity and activity ID, the number of repair entries, and the repair estimate total and currency derived from those entries.

The asset owner field is always sent as empty (null). Event Bridge never sends an asset owner’s name.

On other www.internalfb.com pages, Event Bridge only watches for in-page navigation into a supported route. It does not record or send page content, browsing history, or a list of visited URLs.

Event Bridge does not read, store, or send cookies, page passwords, or Meta session or anti-forgery values. Raw request and response bodies are not stored; only the specific fields listed above are kept.

2.2 Sign-in and account information

To send records to Atrium, the user signs in with Google. Event Bridge opens Google’s sign-in page through Chrome and receives a Google ID token, which it immediately sends to Atrium so Atrium can verify the user. The Google ID token is not stored. Atrium returns:

  • an Atrium access token and refresh token, and
  • the user’s Atrium identity: an employee identifier and display name.

The Atrium tokens are stored locally in extension storage that only the extension’s background service worker can read. They are sent only to Atrium, to authorize delivery and to renew the session. The employee identifier and display name are stored locally to show who is signed in and to attribute work on this computer; they are not included in the workflow event records Event Bridge sends. Atrium can identify the signed-in user from the authorized session, as with any signed-in service.

2.3 Local operational and diagnostic data

Event Bridge stores delivery state (for example queued, delivered, or needs review), timestamps, connection health, extension settings, and appearance preferences on the user’s computer. The popup can show diagnostic summaries (for example queue counts and connection status). Diagnostic data is not sent to any server.

3. How information is used

Information is used only to provide the single purpose described above: to capture supported workflow events, verify them against the workflow system’s own records, keep them safely queued on the computer, deliver them to ComputerCare Atrium, and show the user the extension’s status. Event Bridge contains no advertising, analytics, or tracking code.

4. Where information goes

Event Bridge does not send information to any other party. Information is sent over HTTPS.

5. Storage and retention on the computer

  • Workflow events are written to the computer before any delivery attempt, so they survive restarts and network outages.
  • Events not yet delivered stay on the computer until Atrium confirms them. They are not deleted because of an outage or a failed delivery.
  • Delivered (confirmed) event history is deleted from the computer automatically after 30 days.
  • Lookup context that did not become an event expires after 24 hours.
  • Some converted Track@ Repair observation history is currently kept to rebuild repair state after a restart.
  • Signing out removes the stored Atrium tokens. Uninstalling the extension removes its locally stored data.

Retention of records after they reach Atrium is governed by ComputerCare’s policies for Atrium.

6. Sale, advertising, and other uses

Event Bridge does not sell user data. It does not use or transfer user data for advertising, personalized ads, creditworthiness, or lending purposes, and does not transfer user data to data brokers or information resellers. User data is not used for any purpose unrelated to the single purpose above.

7. Chrome Web Store Limited Use

The use of information received from Chrome APIs and from the supported pages adheres to the Chrome Web Store User Data Policy, including the Limited Use requirements.

8. Security

  • Atrium tokens are kept in background-only extension storage and are never shown in the extension’s interface or written to logs.
  • Sign-in uses Google’s ID-token flow with no client secret in the extension.
  • The extension requests only the permissions it needs: storage, alarms, identity, and access to https://www.internalfb.com/* and https://atrium.computercare.net/*.

9. Changes

We will update this policy when Event Bridge’s data handling changes and will change the effective date above.

10. Contact

Questions about this policy: mammar@computercare.net.